Offset of CST/berger universal prisms
Source:Internet Author:Unknow Pubdate:2008-03-23  
geophyz (Civil/Environme) 25 May 07 12:08
We recently found that some new prisms we bought (CST/berger Universal Series Prisms, model 63-2010) don't have the same offset as another 0/-30 prism that we own (a mini-prism, also by CST/berger). The new prisms seem to have offsets of +7/-23 instead of 0/-30 (relative to the mini-prism - which I trust more based on comparison to another prism). I've tested 8 of the 63-2010's and get the same result with all 8.

I performed the test by setting a pole on a tripod about 12 m from our total station so that the total station and prism were about at the same height. I sighted in the mini-prism and set the 0 azimuth pointing directly at the prism. I then switched the total station into NEZ mode and recorded the position of the prism in both 0 and -30 offsets positions. I then carefully removed the prism from the pole so as not to move the tripod and replaced it with one of the 63-2010's, and measured the position at 0 and -30 offsets. I then swapped the mini-prism back on to make sure nothing had moved, then tested the next 63-2010, etc. There was a difference in height, as expected (the 63-2010's are taller than the mini-prism), but the N reading (the horizontal distance read from the total station to the prism) was consistently off by 6 to 7 mm for all of the 63-2010's. 字串2

Has anyone else observed this amount of difference in offset when comparing two different models of prism? Does anyone else own any of these 63-2010's who would be willing to verify this result? I've been in contact with CST/berger and they apparently checked some of their existing stock and didn't see a problem.

Any input would be appreciated. Thanks.


michaeldouglassewell (Civil/Environme) 27 May 07 4:49
geophyz,
I don't have the model of prism that you mentioned, but I have a couple of dozen different prisms of different types made by different manufacturers. I've tested all of them by forced centering, and I found that they all agreed to within a hundredth of a foot.

Sounds odd too me.

Best regards,
Michael www.sewellconstruction.com






(Click:

Previous:Problem with Nikon DTM 332   Next:survey calculations
[Add TO Favorites] [TOP] [PRINT] [CLOCE WINDOWS]  
  Hot Article
·Friction between soil and r/f
·Pile Soil Spring Constant
·Soil (Sand) Seabed Stiffness
·Equivalent fluid pressure
·soil lateral surchage pressure
·Coefficients of subgrade react
·Light Pole Foundation
·Multi level basement wall
·Thickened Slab Design
·Restrained force-Pole embedmen
·How to analize the lateral for
·Lab soil paramters compared wi
  Related Articles
·survey calculations
·Using same control point for m
·Accurate Distance Measurement
·Trimble Geomatics Office &
·ArcGIS SDK
·Nikon AC-2s
·Help with structural blueprint
·MicroStation J (Ctrl+I)
·Leica Survey Office
·volume calculation
·DGN settings Microstation J
·Gis applications in Geotechnic
Power by DedeCms